High-strength steel wire cables for engineering use are divided into semi-parallel hot-extruded polyethylene steel wire cables and parallel steel wire cable strands.

The semi-parallel hot-extruded polyethylene steel wire cable is made of high-strength galvanized or zinc-aluminum alloy steel wires, closely arranged in a regular hexagon or a missing corner hexagon, twisted slightly with a left-hand twist, and then wrapped with a polyester fiber tape and wrapped outside the steel wire. Hot extruded high-density polyethylene sheathing forms the steel wire bundles. Anchors are installed at both ends of the steel wire bundle by casting, and the final tensile member is formed. Mainly used in cable-stayed bridges, arch bridges, suspension bridge slings, railway stations, airports, structures

Prestressed structures such as sports stadiums and coal sheds, product specifications are φ5x7~φ5x649, φ7x7~φ7x649, and the maximum diameter is φ229mm.

Parallel steel wire rope strands are composed of several high-strength galvanized or zinc-aluminum alloy steel wires, arranged in parallel groups in a regular hexagonal shape, and wrapped around binding tape at certain distances to form rope strands. Anchors are installed at both ends of the cable strands by casting, and the final tensile member is formed. Mainly used in suspension bridge main cables, product specifications are 61 wire, 91 wire, 127 wire and 169 wire.


Hot extruded polyethylene high strength steel wire cable

●Execute GB/T18365-2018 "Hot-extruded polyethylene high-strength steel wire cables for cable-stayed bridges".

●Suitable for building structure cables, bridge cables and slings.

●Special technology for the cable body: double helix (d>90mm), oil filling.

Φ5 cable body parameters

Specification Wire bundle diameter
(mm)
Single sheath diameter
(mm)
Double sheath diameter
(mm)
Single weight of steel wire bundle
(kg/m)
Single weight of cable body
(kg/m)
Cross-sectional area of steel wire bundle
(mm2)
breaking load
(kN)
σb≥1670MPa σb≥1770MPa σb≥1860MPa σb≥1960MPa
Φ5×7 15 22
1.1 1.3 137 230 243 256 269
Φ5×13 22 30
2.0 2.4 255 426 452 475 500
Φ5×19 25 35 40 2.9 3.7 373 623 660 694 731
Φ5×31 32 40 45 4.8 5.7 609 1017 1077 1132 1193
Φ5×37 35 45 50 5.7 6.9 726 1213 1286 1351 1424
Φ5×55 41 51 55 8.5 9.6 1080 1804 1912 2009 2117
Φ5×61 45 55 59 9.4 10.8 1198 2001 2120 2228 2348
Φ5×73 49 59 63 11.3 12.6 1433 2393 2536 2665 2809
Φ5×85 51 61 65 13.1 14.6 1669 2787 2954 3104 3271
Φ5×91 55 65 69 14.0 15.8 1787 2984 3163 3324 3503
Φ5×109 58 68 72 16.8 18.5 2140 3574 3788 3980 4194
Φ5×121 61 71 75 18.7 20.4 2376 3968 4206 4419 4657
Φ5×127 65 75 79 19.6 21.7 2494 4165 4414 4639 4888
Φ5×139 66 78 82 21.4 23.7 2729 4557 4830 5076 5349
Φ5×151 68 79 83 23.3 25.4 2965 4952 5248 5515 5811
Φ5×163 71 83 88 25.1 27.5 3200 5345 5665 5953 6273
Φ5×187 75 87 92 28,8 31.1 3672 6132 6499 6829 7197
Φ5×199 77 89 94 30.7 33.1 3907 6525 6916 7268 7658
Φ5×211 81 93 98 32.5 35.3 4143 6919 7333 7706 8120
Φ5×223 83 95 100 34.4 37.0 4379 7312 7750 8144 8582
Φ5×241 85 97 102 37.1 39.7 4732 7902 8376 8802 9275
Φ5×253 87 101 106 39.0 42.1 4968 8296 8793 9240 9737
Φ5×265 90 105 110 40.8 44.4 5203 8689 9210 9678 10198
Φ5×283 92 107 112 43.6 46.9 5557 9280 9835 10335 10891
Φ5×301 95 111 116 46.4 50.1 5910 9870 10461 10993 11584
Φ5×313 97 113 118 48.2 52.1 6146 10263 10878 11431 12046
Φ5×337 100 117 122 51.9 55.8 6617 11050 11712 12308 12969
Φ5×349 101 118 123 53.8 57.7 6853 11444 12129 12746 13431
Φ5×367 105 121 126 56.6 60.7 7206 12034 12755 13403 14124
Φ5×379 107 123 128 58.4 62.8 7442 12428 13172 13841 14586
Φ5×409 110 128 133 63.0 67.5 8031 13411 14214 14937 15740
Φ5×421 111 129 134 64.9 69.4 8266 13805 14631 15375 16202
Φ5×439 115 133 138 67.7 72.4 8620 14395 15257 16033 16895
Φ5×451 116 135 140 69.5 74.6 8855 14788 15674 16471 17356
Φ5×475 119 137 142 73.2 77.9 9327 15575 16508 17347 18280
Φ5×499 120 139 148 76.9 82.5 9798 16362 17342 18224 19204
Φ5×511 123 143 152 78.8 85.2 10033 16756 17759 18662 19666
Φ5×547 127 147 156 84.3 90.6 10740 17936 19010 19977 21051
Φ5×583 130 150 159 89.9 96.3 11447 19117 20261 21292 22436
Φ5×595 133 153 162 91.7 98.7 11683 19510 20679 21730 22898
Φ5×649 137 157 166 100.0 106.7 12743 21281 22555 23702 24976

Φ7 cable body parameters


Specification Wire bundle diameter
(mm)
Single sheath diameter
(mm)
Double sheath diameter
(mm)
Single weight of steel wire bundle
(kg/m)
Single weight of cable body
(kg/m)
Cross-sectional area of steel wire bundle
(mm2)
breaking load
(kN)
σb≥1670MPa σb≥1770MPa σb≥1860MPa σb≥1960MPa
Φ7×7 21 30
2.1 2.5 269 450 477 501 528
Φ7×13 31 40
3.9 4.5 500 835 886 931 98
Φ7×19 35 45 50 5.7 6.8 731 1221 1294 1360 1433
Φ7×31 44 55 60 9.4 10.7 1193 1992 2112 2219 2338
Φ7×37 49 60 65 11.2 12.8 1424 2378 2520 2649 2791
Φ7×55 5B 68 72 16.6 18.3 2117 3535 3747 3938 4149
Φ7×61 63 73 77 18.4 20.5 2348 3920 4156 4367 4602
Φ7×73 68 78 82 22.0 24.2 2809 4692 4972 5225 5506
Φ7×85 71 83 87 25.6 28.0 3271 5463 5790 6084 6411
Φ7×91 77 89 93 27.4 30.4 3502 5848 6199 6514 6864
Φ7×109 81 93 97 32.8 35.7 4195 7005 7425 7803 8222
Φ7×121 85 99 103 36.4 39.7 4657 7777 8243 8662 9128
Φ7×127 91 105 109 38.2 42.2 4888 8162 8652 9092 9580
Φ7×139 92 107 111 41.8 45.7 5349 8933 9468 9949 10484
Φ7×151 94 109 113 45.5 49.2 5811 9705 10285 10808 11390
Φ7×163 99 114 120 49.1 53.6 6273 10476 11103 11668 12295
Φ7×187 105 121 127 56.3 61.2 7197 12018 12739 13386 14106
Φ7×199 108 124 130 59.9 64.9 7658 12790 13555 14244 15010
Φ7×211 113 129 135 63.5 69.0 8120 13561 14372 15103 15915
Φ7×223 116 133 139 67.1 73.0 8582 14332 15190 15963 16821
Φ7×241 119 135 141 72.5 78.1 9275 15489 16417 17252 18179
Φ7×253 122 139 145 76.2 82.1 9737 16260 17234 18111 19085
Φ7×265 127 144 150 79.8 86.3 10198 17031 18050 18968 19988
Φ7×283 129 147 153 85.2 91.8 10891 18188 19277 20257 21346
Φ7×301 133 151 157 90.6 97.4 11584 19345 20504 21546 22705
Φ7×313 135 154 160 94.2 101.3 12046 20116 21321 22406 23610
Φ7×337 141 160 166 101.4 109.0 12969 21659 22955 24122 25419
Φ7×349 142 162 168 105.0 112.7 13431 22430 23773 24982 26325
Φ7×367 147 167 173 110.5 118.6 14124 23587 24999 26271 27683
Φ7×379 149 170 178 114.1 123.1 14586 24358 25817 27130 28589
Φ7×409 155 176 184 123.1 132.6 15740 26286 27860 29276 30850
Φ7×421 155 177 185 126.7 136.0 16202 27057 28678 30136 31756
Φ7×439 161 183 191 132.1 142.4 16895 28214 29904 31425 33114
Φ7×451 163 185 193 135.8 146.2 17357 28985 30722 32284 34020
Φ7×475 166 190 198 143.0 153.9 18280 30528 32356 34001 35829
Φ7×499 169 193 202 150.7 160.7 19204 32070 33991 35719 37639
Φ7×511 172 197 206 154.4 165.3 19666 32841 34808 36578 38545
Φ7×547 177 204 213 165.3 176.4 2105 35155 37260 39155 41260
Φ7×583 182 209 218 176.1 187.8 22436 37469 39713 41732 43975
Φ7×595 186 213 222 179.8 192.5 22898 38240 4530 42591 44881
Φ7×649 192 220 229 196.1 208.6 24976 41711 44208 46465 48954


Products Show:


Other Related Products:

Instructions for use of cable

Instructions for using the cable:

01

After the cable product arrives at the designated location, it must be hoisted with fiber tape to protect the surface of the cable and the packaging from damage. The hoisting method adopts three-point hoisting, and the hoisting process needs to be carried out with care. (See Figure 1) During the lifting process, the cable should be prevented from colliding with other objects, causing damage to the cable. (See Figure 2)

The storage location for cable products should be dry, with the bottom padded with sleepers and completely covered with rain-proof cloth.

02

The storage location for cable products should be dry, with the bottom padded with sleepers and completely covered with rain-proof cloth. When stacking stay cables, sleepers should be used to cushion each layer of stay cables, and they should be stacked neatly, with no more than two bundles at most (see Figure 3).


03

The diameter of the cable is less than 50mm. The cable with a short length (less than 10m) can be directly hoisted and released by a crane (the cable should be left for a period of time to release the internal stress after the cable is released). The diameter is greater than 50mm and the length is longer. It is advisable to use a special cable tray to place the cable (see Figure 4). The main cable should be placed using a special cable tray (Figure 5).


04

Before placing the cables, steel bars and other hard sharp objects at the construction site should be cleaned up; avoid contact between the cable body and the ground. Smooth rubber rollers should be laid on the ground, and vertical protective rollers should be set up to ensure that the cable body is not scratched by hard objects on the ground during construction. .

05

During the pulling process of the cable, necessary special lifting clamps and traction tools must be used. The clamps are lined with rubber washers and then fixed on the surface of the cable body. It is strictly prohibited to directly bundle the steel wire rope on the surface of the steel cable sheath to avoid collision between the steel rope and other steel components (see Figure 6).

06

The packaging material wrapped around the cable is a protective layer that prevents the cable from direct contact with the outside world. It can also prevent contact scratches on the cable during transportation and release. At the same time, it also prevents external debris from contaminating the surface of the colored cable body after the cable is hung. Therefore, it is recommended not to open the packaging before the completion of the project. It is best to remove it after the completion of the project to ensure that the colored PE cable is intact and the color is intact. consistent.

07

When adjusting the cable tension, a special wrench or tool should be used to adjust the anchor, and a pad should be added between the two. It is strictly forbidden to use chain pliers, vise and other tools for direct loading to prevent damage to the surface protective layer.

08

The surface of the cable anchors is electro-galvanized before leaving the factory. Each batch of cables should be installed as soon as possible after arriving at the site. After installation, all exposed anchors of the cables should be repainted (painted). The painting method can be the same as that of the steel structure. Anti-corrosion grease should be applied to the exposed threaded parts, and the joints should be protected with sealing silicone to prevent corrosion. Ensure the protective performance and service life of the cable.

09

For high vanadium coated cables, the cable body will be tightened with iron wires before leaving the factory. The iron wires should not be removed before installation and tensioning to prevent skipping or drumming of the cable body.

Cable Fittings:






Health Monitoring

System Structure

Description of main features of the system

01 System measurement accuracy: 1.5%F.S;

02 Sensor installation method: installed inline at each anchor plate, meeting the IP67 protection level, and realizing the function of the rigging's own measuring device;

03 Sensor calibration method: The rigging is calibrated before leaving the factory, and no calibration is required on site;

04 The collection equipment is installed on the sensor side and connected through wired cables. The collection equipment is wirelessly transmitted to the network management gateway, and the gateway transmits it to the cloud platform through the GPRS network for display, storage and query, and the data collection granularity can be set;

05 The system can automatically complete remote data transmission. The cloud platform center processes and analyzes the measured data, and can realize the function of sending detection data reports and over-value warning information to the client. It has strong compatibility, and the measurement end, collection end, and platform can all implement standardized data interfaces to facilitate customer data application or development.

The entire system is divided into perception layer, collection and transmission layer, cloud processing layer and application layer. The sensing layer installs sensors through welding to realize real-time monitoring of the load stress of the rigging. The acquisition device collects signals and transmits them to the cloud platform through the ZIGBEE/GPRS wireless network. The cloud platform center processes and analyzes the uploaded data. Finally, Test results, data reports, and early warning confidence are sent to the client.


Software Application

The software application is mainly based on the rigging requirements, briefly sorting out the framework and function points of existing localized products, cloud platforms, and considering the support for the rigging detection system. The system can provide a good human-computer interaction interface to facilitate user operation and has the following functions:


Perception System


Smart Cable

Cables are widely used in large structures such as large bridges and have very important social significance and economic value to the bridge operation department. Intelligent cables will generally adopt institutional health detection technology that installs the detection system on the bridge after the bridge is completed, leaping to the point where the detection system and the structural system are truly organically integrated.


Working Principle

The intelligent cable system consists of intelligent induction nuts, cable bodies and other cable components, collection and transmission equipment, cloud and application terminals. When the cable is stressed, strain can be induced on the cable nut and cable body, and the acquisition equipment can collect the data at the sensing end and transmit it to the cloud through wired or wireless transmission, so that the detection data can be directly viewed or processed.


Intelligent Cable Force Measurement Process

① Intelligent cable production → ② Intelligent cable calibration → ③ On-site installation and layout of cable and equipment → ④ Load monitoring, of which ① and ② are completed in the factory, and ③ and ④ are implemented at the construction site. The development of smart cables can realize the load detection of the cable during tensioning and long-term load monitoring after anchoring, and at the same time realize portable installation, which can meet the construction requirements of current structures.



Smart Steel Tie Rod

Steel tie rods have the advantages of high strength, good toughness, economy and applicability, and have been widely used as direct units in prestressed steel structures. Whether the prestressed steel tie rods meet the design requirements during construction will be directly related to the load-bearing capacity and safety performance of the prestressed structure. Therefore, the detection and monitoring of its internal forces have become an important part of the construction stage. At present, the force measurement methods of steel tie rods mostly use the torque coefficient method or the hydraulic conversion method. The measurement results are affected by many factors, and the comprehensive factors are relatively large. It is difficult to meet the current construction requirements of prestressed steel structures. Smart steel tie rods are designed to realize the sensing and monitoring of structures through a set of smart steel tie rod systems. Provide effective evaluation data for construction personnel, construction and operation units, and colleagues on site Achieve convenient, fast, safe and effective installation.

Working Principle

The smart steel tie rod system consists of steel tie rod components such as induction fork lug pins or smart connections, collection and transmission equipment, cloud, and application terminals. The sensing principle adopts principles such as vibrating wire and resistance. When the steel tie rod is stressed, it can be sensed on the fork lug pin or connecting sleeve. The data of the sensing section is collected through the acquisition and transmission equipment and transmitted to the cloud through wired or wireless transmission. On the application side, you can directly check the stress status of the steel tie rod or process the detection data.



Smart Steel Tie Rod Force Measurement Process

① Production and production of smart steel tie rods → ② Calibration of smart steel tie rods → ③ On-site installation and layout of steel tie rods and equipment → ④ Load monitoring, of which ① and ② are processed in the factory, and ③ and ④ are implemented at the construction site.

The development of smart steel tie rods can realize load detection of steel tie rods during tensioning and long-term load monitoring after installation, while also achieving portable installation, which can meet the construction requirements of current structures.

Fork lugs, tie rods, smart connection sleeves

Portable display signal cable cloud terminal display equipment

Collection and transmission equipment



Advantage comparison

1High compatibility

Intelligent rigging itself is a system that can be connected to other subsystems as a main system or integrated into other systems as a subsystem. It has high compatibility; traditional sensors have poor compatibility and are incompatible with many systems and have great limitations.

2 System implementation efficiency

The system can be quickly brought online without complicated wiring.

3 On-site installation efficiency

Intelligent sensors, cables and rigging adopt integrated equipment or installation, which does not affect the normal installation and use of rigging, and the system adopts a wireless distributed design. Traditional sensors require on-site technical guidance from professionals for installation, and no wiring is required on-site, reducing on-site implementation and maintenance costs.

Engineering Project Cases Catalogue Download:

Package and Factory Show:



Product Inquiry

Φ40-Φ140 Anchor Cup Anchor (Seal Cable), Hot Cast Anchor Cup Nut Type

Φ40-Φ140 Ring Cable Anchor(Seal Cable), Hot Cast Anchor Ring Type

Φ40-Φ140 Lug Anchor(Seal Cable), Hot Cast Anchor Lug Screw Adjustment Type

Closed Cable Body, Sealed Steel Wire Rope, Seal Cable

Φ40-Φ140 Anchor Cup Anchor (High Vanadium Cable Body), Hot Cast Anchor Cup Nut Type